Mask Testing Solution
GESTER Mask Testing machine for flat mask, N95 mask, ffp mask test. One-stop service. In stock, Fast delivery. all Mask Tester meet the standard: EN 14683, EN149, EN143, ASTM F2100,NIOSH-42 CFR84, GB2626, YY /T0969, GB/T 32610.
BS EN 14683-2019 Mask Testing Equipments
Standards |
Specifications |
Standards point |
GESTER Products |
Pictures |
Operational environment |
BS EN 14683-2019 Medical face masks - Requirements and test methods |
Bacterial filtration efficiency (BFE) |
5.2.2 5.2.7 |
|
Sterile laboratory |
|
Breathability (Differential Pressure ) |
5.2.3 |
|
Temperature and humidity laboratory |
||
Splash resistance |
5.2.4, |
|
Routine laboratory near pretreatment box |
||
ISO 22069 |
|
|
|
||
Microbial cleanliness (Bioburden) |
5.2.5, |
/ |
|
|
|
ISO 11737-1 |
|
|
|
||
Biocompatibility |
5.2.6, |
/ |
|
|
|
ISO 10993 |
|
|
|
||
Summary of performance requirements |
5.2.7 |
5.2.2----5.2.5 test |
|
|
EN149 Mask testing equipments
Standards |
Specifications |
Standards point |
GESTER Products |
Pictures |
Operational environment |
EN149 Filtering half masks to protect against particles-Requirements, Testing, marking |
Simulated wearing treatment |
8.3.1 |
|
Sterile laboratory |
|
Temperature conditioning Flow conditioning |
8.3.2 8.3.4 |
|
Sterile laboratory |
||
Mechanical strength |
8.3.3 |
GT-RB01 Filter Oscillation Test Chamber |
|
Sterile laboratory |
|
Leakage |
8.5 |
|
Temperature and humidity laboratory |
||
Flammability |
8.6 |
GT-RA06 Mask Flame Retardant Tester |
|
Fume hood |
|
Carbon dioxide content of the inhalation air |
8.7 |
GT-RA05 Air-purifying Particle Respiratory Protective Tester |
|
Room temperature 16-32 degrees |
|
Strength of attachment of exhalation valve housing |
8.8 |
|
Temperature and humidity laboratory |
||
Breathing Resistance |
8.9 |
|
Sterile laboratory |
||
Clogging |
8.10 |
GT-RA13 Masks Clogging Tester |
|
Sterile laboratory |
|
Penetration of filter material |
8.11 |
|
ASTM F2100-2019 Mask Testing Machine
ASTM F2100-2019 Standard Specification for Performance of Materials Used in Medical Face Masks |
Bacterial Filtration Efficiency |
9.1, |
|
Sterile laboratory |
|
ASTM F2101 |
|||||
Differential Pressure |
9.2, |
|
Temperature and humidity laboratory |
||
EN 14683 Annex C |
|||||
Sub-Micron Particulate Filtration |
9.3, |
GT-RA09 PFE testing machine |
|
Humidity 30%±10% |
|
ASTM F2299 |
Temperature 25±5degree |
||||
Resistance to Penetration by Synthetic Blood |
9.4, |
|
Routine laboratory near pretreatment box |
||
ASTM F1862 |
|||||
Flammability |
9.5, |
|
Fume hood |
||
16 CFR Part 1610 |
NIOSH-42 CFR84 Mask Testing Equipments
Standards |
Specifications |
Standards point |
GESTER Products |
Pictures |
NIOSH-42 CFR 84 APPROVAL OF RESPIRATORY PROTECTIVE DEVICES |
Airflow resistance tests. |
84.180. |
|
|
Non-powered air-purifying particulate filter efficiency level determination |
84.181 |
|
||
Exhalation valve leakage test; minimum requirements. |
84.182 |
|